"; i.id = "GoogleAnalyticsIframe"; if ("MutationObserver" in win) { new MutationObserver(function onDocumentChange() { if (d.body) { appendAnalytics(i, d.body.firstChild); this.disconnect(); } }).observe(d, { subtree: true, childList: true }); } else { appendAnalytics(i, d.getElementsByTagName('script')[0]); } })(document, window);
MercadoLíder
+1000
Ventas concretadas
Brinda buena atención
Product introduction:
One:
1.Omron 5V solid-state relay, 240V/2A, fuse with resistance 240V/2A.
2.input power supply: 5V DC (160MA)
3. input control signal voltage:
(0-2.5V, low level status, relay OFF)
(3-5V, high level status, relay ON)
4. More convenient to use KF301 port for control line connecting.
Two. Module interface:
1. Input:
DC+: connect power positive VCC(power supply according to relay voltage)
DC-: connect power negative GND
CH1: signal trigger end of relay module contact 1 (high level trigger)
CH2: signal trigger end of relay module contact 2 (high level trigger)
CH3: signal trigger end of relay module contact 3 (high level trigger)
CH4: signal trigger end of relay module contact 4 (high level trigger)
CH5: signal trigger end of relay module contact 5 (high level trigger)
CH6: signal trigger end of relay module contact 6 (high level trigger)
CH7: signal trigger end of relay module contact 7 (high level trigger)
CH8: signal trigger end of relay module contact 8 (high level trigger)
2. Meaning of high level and low level:
High level trigger refers to a forward voltage between the signal trigger end (CH) and the power negative pole. The trigger is usually realized by connecting power positive end to the signal trigger end. When the trigger end has positive voltage or voltage reaches the trigger point, relay is closed.
Low level trigger refers to a 0V between the signal trigger end and the power negative pole, or the voltage of the trigger end is lower than that of the power positive pole, which reaches the level of trigger point, the relay is closed. The trigger is usually realized by connecting power negative end to the signal trigger end.
Electrical parameters:
Voltage quiescent current working current trigger voltage trigger current
Contact 1 5V 0mA 13.8mA 3-5V 2mA
Contact 2 5V 0mA 26.8mA 3-5V 2mA
Contact 3 5V 0mA 37mA 3-5V 2mA
Contact 4 5V 0mA 48mA 3-5V 2mA
Contact 5 5V 0mA 59mA 3-5V 2mA
Contact 6 5V 0mA 70mA 3-5V 2mA
Contact 7 5V 0mA 81mA 3-5V 2mA
Contact 8 5V 0mA 90mA 3-5V 2mA
Three. Product instruction: